The principle of the electrostatic film edge pinning system machine is to use high voltage direct current to break down the air, form an ion current and an electrostatic field between the positive and negative electrodes, and tightly adsorb the film between the positive and negative electrodes on the mirror cooling roller with the negative electrode to make the film Rapid cooling ensures stable film width and production. Locking line speed 400m/min, stable and reliable.
Technical parameters: ①input voltage AC220V 60hz; ②output voltage 0-20KV continuously adjustable;
Scope of application: film edge fixing of various cast film units.
Instructions for use:
1. Please read the operating instructions before following the operation;
2. Do not approach or touch the tip of the static electricity generating rod with your hands or other conductive objects to prevent the danger of electric shock;
3. After the power supply is disconnected, there will still be residual voltage at the output terminal. Please do not approach or touch it. If necessary, use a short-circuit wire or a bleeder resistor to discharge.
Installation and operation:
The main cabinet of the static bar should be placed in a well-ventilated place, the power socket used must have a grounding pin, and confirm that there is a well-grounded grounding wire. Otherwise, it will be dangerous in use
, Our company is not responsible for the losses caused by this.
The static electricity generating rod should be installed in a suitable position, and there should be no grounded conductor nearby, and it is not easy to be touched by the human body to prevent discharge and electric shock.
After installing the static generator and rod, confirming that the power supply is correct and the grounding is good, choose the appropriate output voltage polarity, first turn all the adjustment knobs counterclockwise to the minimum, turn on the power switch on the front panel of the host, and see the power indicator light is on Then, slowly turn the selected knob clockwise to a suitable position.
After each use, please adjust the voltage adjustment knob to the minimum position and turn off the power switch to prevent sudden high voltage output when the machine is turned on next time, which may cause electric shock.